Connections Following connections
are on the rear side:
• RS232 for connecting
the pre-heating plate or
a PC.
• Connection for manual
control panel or foot switch.
Air
generation The
airflow rate is controlled
digitally by means of
a proportional valve.
Alternatively, an inert
gas, such as nitrogen
could be used in place
of compressed air for
more demanding tasks.
ESD
safe Housing
and iron are ESD safe.
Technical
data WHA3000V: Dimensions:
9.5" x 10.6"
x 4.0"
(W x L x H) (240 x 270 x
100mm) Mains
voltage: 120 V Max.
heat power: 700 W Temperature
range: 150°F
– 999°F
(50°C – 550 °C) Control
accuracy: ±
77°F
(± 25°C) Air
volume: 5 –
50 l/min. Max.
vacuum: -0.6 bar
Compressed air supply /
Inert gas (N2): 4 –
6 bar
Connections Compressed
air / inert gas 4 –
6 bar.
Temperature
check Connection
of the temperature sensor
(available as an accessory)
for highly accurate process
monitoring.