Nozzle
selection
To select a suitable nozzle for your application,
observe the following:
1. The ND and NQ nozzles have an integrated
pre-heating plate for pre-heating components by
means of contact heat. Air outlet slots are located
around the plate with a width of approx. 1 mm
for the hot air.
2. The nozzle dimensions named in the brochure
correspond to inside dimensions. The dimensions
of the integrated pre-heating plate are calculated
by subtracting the air outlet slot dimension from
the nozzle dimensions.
3. Ensure that the component is not larger than
the integrated pre-heating plate to avoid obstruction
of the air outlet.
4. The type D (Dual) nozzles have air outlet
slots on two opposing sides. Dimension designates
the lengths of the heated side.
5. The type Q (Quad) nozzles have air outlet
slots on all four sides.
As the transfer of heat for the reflow process
is mainly by means of contact heat of the nozzle
plate, the hot air nozzle must "fit"
exactly. A tolerance of a few 0.1 mm during nozzle
selection is perfectly acceptable and does not
have a negative influence on desoldering quality. |